WELCOME TO NDT ALAT UJI INDONESIA | ALAT UJI NON DESTRUTIVE TESTING
Coating Thickness Gauge TIME2511

Coating Thickness Gauge TIME2511


















Description

TIME2511 coating thickness gauge is an economical model integrated with F probe. It can nondestructively measure the thickness of non-magnetic coatings (such as zinc, aluminum chrome, copper, rubber, paint and so on) on ferrous metals (such as steel, iron, alloyed metals, hard magnetic steel and so on). It has the feature of being easy  to calibrate on zero point, high speed data collection and providing single point measurement mode, automatic shutting off. In addition, the gauge has the function of metric and imperial conversion, which means users can select mm or inch according to their specific requirement. It can fast, exactly and nondestructively measure the thickness of coating and plating.


Feature

• Measuring method: magnetic induction (F)
• Economical model with F probe integrated
• Single point measurement mode
• Easy calibration on zero point
• 3 kinds of adjustable resolution for different application
• High speed data collection
• Automatically switch off
• Easy conversion between mm and inch


Spesification

Operating principleMagnetic induction
Measuring range0 ~ 1250 μm
3 adjustable resolution1μm, 5μm, 10μm
Measuring accuracy1μm ± (3%H + 1μm)
5μm ± (3%H + 5μm)
10μm ± (3%H + 10μm)
Power supply Battery 1.5 Standard AAA type (2pcs)
Operation temperature0 ºC~ 40 ºC (32 ºF ~ 104 ºF)
Humidity20% RH ~ 90% RH
Dimension110mm x 50mm x 23mm
Weight100g
High Accuracy Coating Thickness Gauge CCT01

High Accuracy Coating Thickness Gauge CCT01


















Description 

This compact gauge can be used for non-destructive coating thickness measurement of non-magnetic coatings, e.g. paint, enamel, chrome on steel, and insulating coatings, e.g. paint and anodizing coatings on non-ferrous metals.

The internal probe can work on both principles, magnetic induction and the eddy currents. The probe can automatically detect the substrates type (Magnetic or not), and calculate the coating thickness and display it fast.
There are five data groups, and readings will be automatically stored to memory for general groups (Not for direct group). Each group has individual statistics, alarm limit settings and calibration. User can recall and delete specified readings easily.

User does all operations via standard menu so easily. User can press the CAL button to start calibration freely


Feature

  •  128*128 dot matrix LCD display, standard menu operations;
  •  Two group mode: direct (DIR) and general(GEN), readings will be lost when power off in  direct mode, and not be lost in general mode. 80 readings can be stored for each group;
  •  Zero point calibration and multi-point calibration(up to 4 points) for each group
  •  Statistics display: mean, minimum, maximum and standard deviation;
  •  User can recall, delete specified readings, or delete group readings;
  •  Two measure mode: single and continuous;
  •  Three probe mode: auto, magnetic and eddy current;
  •  User can set high or low limit alarm for each group;
  •  Power off automatically;
  •  USB interface to data transmission;
  •  Low battery and error indication



Spesification


* Measuring principle: Magnetic induction (F-probe) and eddy current (N-probe);
* Measuring range: 0 to 1300um (0 to 51.2mils); 
* Accuracy: ± (3% of readings+2um); ± (3% of readings+0.078mils); 
* Resolution: 0um~999um (1um), 1000um~1300um (0.01mm);
              0mils~39.39mils (0.01mils), 39.4mils~51.2mils (0.1mils); 
* Calibration: One to four point calibration, zero calibration; 
* Data Group: One direct group (readings not be stored to memory), four general group (readings can be stored), and each group have individual statistics, alarm settings and calibration; 
* Statistics: No. of readings, mean, minimum, maximum and standard deviation; 
* Units: um, mm and mils; 
* Alarm: User can set the high/low alarm, and alarm icon displayed on LCD when over the limit; 
* Minimum curvature radius: convex 1.5mm(59mils) and concave 25mm(984mils);
* Minimum measuring size: Diameter 6mm(236mils);
* Minimum thickness of substrate: F-probe: 0.5mm(0.02"), N-probe: 0.3mm(0.012");
* Computer interface: Download data via USB interface;
* Power supply: Two 1.5v AAA battery;
* Operation temperature: 0°C to 40°C(32°F to 104°F);
* Storage temperature: -20°C to 70°C(-4°F to 158°F);
* Size: 110mm*53mm*24mm (4.33"x2.09"x0.94");
* Weight: 92g (3.24oz)
TT210

TT210

















Description

Alat ukur ketebalan lapisan seperti cat, epoxy, kertas, plastik dan lain-lain yang basenya magnetik atau non magnetik


Feature

  • Two measuring methods: magnetic induction (F) and eddy current (N)
  • Magnetic induction (F) method is used to measure the thickness of non-magnetic coating on ferrous metal
  • Eddy current (N) method is used to measure the thickness of non-conducting coating on non-ferrous materials
  • Automatic recognition of substrate
  • Automatic selection of measuring methods
  • 5 statistical ways: Mean values / Max. values / Min. values / testing numbers.(No.) / standard deviations (S.DeV)
  • Upper-lower limit setting and sound alarm
  • Data output to printer or PC by RS232 cable
  • 500 readings can be stored
  • 2 measuring modes: continuous / single
  • 2 stop ways: Manual/automatic


Spesification


Probe types
F
N
Measuring methods:
magnetic induction
eddy current
Measuring range:
0 to 1250 μm
0 to 1250 μm
0 to 40μm (for chromeplate on copper)
Minimum resolution:
0.1μm
Tolerance :
One point calibration
±(3%H+1)
± (3%H+1.5)
H means the thickness of tested piece
Two points calibration
±[(1~3)%H+1]
±[(1~3)%H+1.5]
H means the thickness of tested piece
Measuring condition
Min. curvature radius (mm)
Convexity 1.5
Convexity 3
Min. testing area diameter (mm)
Φ7
Φ5
Critical thickness of substrate
0.5
0.3
Power supply
Battery AAA 1.5V  (2pcs)
Working Temperature
0-40°C
Dimensions
110mm×50mm×23mm
Weight
100g

Paint Coating Thickness Meter Gauge F Probe 1000?m CM8821

Paint Coating Thickness Meter Gauge F Probe 1000?m CM8821



















Description

Use it anywhere -- Suitable for the laboratory, Powder Coating Companies, Manufacturing Companies, Paint Suppliers, Manufacturing Companies, Steel and Aluminum Refinishing, Automobile Dealers, Auto Auctions, Body Shops, Auto Detailers and any company needing a highly accurate measurement of the dry coating thickness and can be used even in harsh field conditions.

Feature
  • Has CE marking, conforms with the essential health and safety requirements set out by the European Directives
  • Conforms to international standards and passed the standards of ISO2178
  • Suitable for the laboratory and for use in harsh field conditons
  • Widely used to measure the thickness of non-magnetic materials (e.g. paint, plastic, porcelain enamel, copper, zinc, aluminium, chrome, etc. ) on magnetic materials (e.g. iron, nickle, etc. ) often used to measure the thickness of plating layer, lacquer layer, porcelain enamel layer, phosphide layer, copper tile, aluminium tile, some alloy tile, paper, etc.
  • Used the exclusive Micro-computer LSI circuit and crystal time base to offer high accuracy measurement and fast measuring time
  • Performs Automatic Calibration when no substrate or metal substrates are near the sensor probe
  • Allows re-calibration using the included iron subrate block or an uncoated standard
  • With wide measuring range of 1000µm/0-40mil and high resolution
  • Digital display gives exact reading with no guessing or errorsDurable, long-lasting components with strong but light weight ABS-plastic housing assures maintenance free performance for many years. The housing had been carefully shaped to fit comfortably in either hand.
  • Use it anywhere -- Suitable for the laboratory, Powder Coating Companies, Manufacturing Companies, Paint Suppliers, Manufacturing Companies, Steel and Aluminum Refinishing, Automobile Dealers, Auto Auctions, Body Shops, Auto Detailers and any company needing a highly accurate measurement of the dry coating thickness and can be used even in harsh field conditions.


Spesification




  • Operating Principle: Magnetic Induction (F)
  • Measuring Range:0~1000µm / 0~40mil
  • Resolution:
  • 0.1µm (0~99.9µm)
  • 1µm (over 100µm)
  • Accuracy: ±1~3%n or ±2.5µm (whichever is greater)
  • Min. measuring area: 6mm
  • Min. sample thickness: 0.3mm
  • Metric/ imperial: convertible
  • Auto power off
  • Automatic Calibration (when no other metal substrate near the probe sensor upon switching on)
  • Display: 4 digits, 10mm LCD.
  • Operating conditions:
  • Temperature 0~50°C (or 32~122 in °F)
  • Humidity <80%
  • Battery indicator: Low Battery IndicatorPower supply: 4 x AA 1.5V battery
  • Dimensions (main unit): 67 x 168 x 31mm
  • Weight:
  • Main Unit: 155g (battery excluded)
  • Whole Packaging: 690g (battery excluded)
Sound Level Meter BE804

Sound Level Meter BE804

















Description

Auto Backlight. Just press one button readings are instantly displayed. A practical little tool great for noise pollution monitoring, home theater setup, health and safety compliance, vehicle noise testing, etc.


Feature
* Measuring Range: 30 ~ 130dBA
* Accuracy: 1.5dB
* Resolution: 0.1dB
* Frequency Range: 31.5HZ ~ 8.5KHZ
* Frequency Weighting: A
* Sampling Frequency: 2 times/sec
* Digital Display: 4 digits
* Microphone: 1/2" Electret Condenser microphone
* Auto Power Off
* Low Battery Indication
* Max Hold Function
* Operating Condition
 Temperature: 0~40°C (32 ~ 104°F )
Humidity: 10~80%RH
* Storage Condition
Temperature: -10~60°C  (14 ~ 140°F )
Humidity: 10~70%RH
* Power Supply: 1 x 9V Battery (included)
* Dimension: 57 x 26 x 149mm
* Weight: 144g (including battery)





Thermometer S-H04

Thermometer S-H04

















Description

Termometer ini terlihat seperti jarum ekstra besar dengan pengukur suhu di ujungnya. Ini memberikan hasil yang dapat diandalkan ketika Anda ingin pembacaan pengukuran akurat dari suhu internal dan ambient. Ini meteran temperatur elektronik juga dapat digunakan dalam mendapatkan suhu makanan. Probe dapat mengukur suhu yang berkisar dari -50 ° C ~ 300 ° C (-58 ~ 572 ° F). Readouts mudah dibaca digital memiliki layar besar yang dengan cepat menampilkan suhu baik Fahrenheit (° F) atau Celcius (° C) hanya dengan menekan satu

Feature
  • Besar mudah dibaca layar LCD
  • Dapat menahan -50 ~ 300 ° C / -58 ~ 572 ° F pengukuran temperatur
  • Ukur suhu yang baik INTERNAL & AMBIENT
  • ° C / ° F beralih dengan menampilkan membaca di Fahrenheit (° F) atau Celcius (° C)
  • Membaca suhu dalam waktu 2 detik
  • 10 menit auto power-off untuk menghemat baterai
  • 140mm stainless steel penginderaan batang
  • Tahan air PVC Keyboard
  • Hubungi ukur & portabel
  • Stabilitas jangka panjang dengan pembacaan sangat akurat
  • Kualitas profesional untuk kinerja dan akurasi
  • Disertakan dengan kasus untuk melindungi sensor
  • Diterapkan pada refrigeran, pemanasan dan pengolahan makanan


Spesification

     Thermometer untuk memeriksa suhu makanan internal yang
     12  30mm Digital display jelas menunjukkan suhu saat
     Push-tombol kontrol menawarkan on / off, Switch º C / º F
     Otomatis menutup-off setelah 10 menit
     Durable penyelidikan stainless steel adalah 5,5 "panjang
     Memenuhi persyaratan HACCP
     Akurasi pembacaan -30-300 º C (-22-572 ° F)
     Resolusi tinggi 0.1 "º C / º F" Kendali berbagai
     Akurasi: ± 1,0 º C dalam waktu 0 ~ 100 º C, ± 2,0 º C jika ranger.
     Unit size: 220 (L) x26 (W) x15 (T) mm
     Ukuran Layar: 29x14mm, tahan air PVC Keyboard
     1.5V (LR44) baterai jam alkaline (terpasang)

Coating Thickness Gauge TIME2511

Coating Thickness Gauge TIME2511


















Description

TIME2511 coating thickness gauge is an economical model integrated with F probe. It can nondestructively measure the thickness of non-magnetic coatings (such as zinc, aluminum chrome, copper, rubber, paint and so on) on ferrous metals (such as steel, iron, alloyed metals, hard magnetic steel and so on). It has the feature of being easy  to calibrate on zero point, high speed data collection and providing single point measurement mode, automatic shutting off. In addition, the gauge has the function of metric and imperial conversion, which means users can select mm or inch according to their specific requirement. It can fast, exactly and nondestructively measure the thickness of coating and plating.


Feature

• Measuring method: magnetic induction (F)
• Economical model with F probe integrated
• Single point measurement mode
• Easy calibration on zero point
• 3 kinds of adjustable resolution for different application
• High speed data collection
• Automatically switch off
• Easy conversion between mm and inch


Spesification

Operating principleMagnetic induction
Measuring range0 ~ 1250 μm
3 adjustable resolution1μm, 5μm, 10μm
Measuring accuracy1μm ± (3%H + 1μm)
5μm ± (3%H + 5μm)
10μm ± (3%H + 10μm)
Power supply Battery 1.5 Standard AAA type (2pcs)
Operation temperature0 ºC~ 40 ºC (32 ºF ~ 104 ºF)
Humidity20% RH ~ 90% RH
Dimension110mm x 50mm x 23mm
Weight100g
Thermometer DT-130-131

Thermometer DT-130-131
















Description

DT-130/131 termometer kontak menawarkan respon yang cepat dan akurasi laboratorium. Termometer ini menawarkan 0,1 ° C/0.1 ° F resolusi atas seluruh rentang pengukuran. Sebuah sarung kasar melindungi kedua model

Feature

  • Besar mudah dibaca layar LCD
  • Dapat menahan -40 ° CTO 250 ° C / -40 ° Fto 482 ° F. pengukuran temperatur
  • Ukur suhu yang baik INTERNAL & AMBIENT
  • ° C / ° F beralih dengan menampilkan membaca di Fahrenheit (° F) atau Celcius (° C)
  • Membaca suhu dalam waktu 2 detik
  • 20 menit auto power-off untuk menghemat baterai
  • 118mm stainless steel penginderaan batang
  • Stabilitas jangka panjang dengan pembacaan sangat akurat
  • Kualitas profesional untuk kinerja dan akurasi
  • Disertakan dengan selubung plastik untuk melindungi sensor
  • Diterapkan pada refrigeran, pemanasan dan pengolahan makanan

Spesification

Contact thermometers offer fast response and laboratory accuracy.
Range:-40°Cto 250°C /-40°Fto 482 °F.
Basic Accuracy:±1.5%
offer 0.1°C/0.1°F resolution over the entire measurement ranges.
A rugged holster protects.
User Selectable °C or °F
Sampling time 2.0 seconds
LCD display
Auto Power Off(after approx.20 minutes)                                             
Probe length:11.8cm
Product size: 21.5cmx3.2cmx1.9cm
Max/Min Hold and Data Hold( FOR DT-131)

Thermometer DT-130-131

Thermometer DT-130-131
















Description

DT-130/131 termometer kontak menawarkan respon yang cepat dan akurasi laboratorium. Termometer ini menawarkan 0,1 ° C/0.1 ° F resolusi atas seluruh rentang pengukuran. Sebuah sarung kasar melindungi kedua model

Feature

  • Besar mudah dibaca layar LCD
  • Dapat menahan -40 ° CTO 250 ° C / -40 ° Fto 482 ° F. pengukuran temperatur
  • Ukur suhu yang baik INTERNAL & AMBIENT
  • ° C / ° F beralih dengan menampilkan membaca di Fahrenheit (° F) atau Celcius (° C)
  • Membaca suhu dalam waktu 2 detik
  • 20 menit auto power-off untuk menghemat baterai
  • 118mm stainless steel penginderaan batang
  • Stabilitas jangka panjang dengan pembacaan sangat akurat
  • Kualitas profesional untuk kinerja dan akurasi
  • Disertakan dengan selubung plastik untuk melindungi sensor
  • Diterapkan pada refrigeran, pemanasan dan pengolahan makanan

Spesification
Contact thermometers offer fast response and laboratory accuracy.
Range:-40°Cto 250°C /-40°Fto 482 °F.
Basic Accuracy:±1.5%
offer 0.1°C/0.1°F resolution over the entire measurement ranges.
A rugged holster protects.
User Selectable °C or °F
Sampling time 2.0 seconds
LCD display
Auto Power Off(after approx.20 minutes)                                              
Probe length:11.8cm
Product size: 21.5cmx3.2cmx1.9cm
Max/Min Hold and Data Hold( FOR DT-131)

Sound Level Meter BE824 - BE844

Sound Level Meter BE824 - BE844




















Description

This high-precision high quality high accuracy Sound Level Meter (30 to 130 Decibels) has been designed to meet the measurement requirement of Safety Engineers, Health, Industrial Safety offices and Sound Quality control in various environment.


Feature
* Measuring Level: 30-130dB (A) , 35-130dB (C)
* With Software CD & USB Cable, for recording date into your PC( only for model BE844)
* Level Ranges: 30-80dB ;50-100dB ;60-110dB ;80-130dB ;30-130dB
* Accuracy: ±1.5dB (under reference conditions)
* Resolution: 0.1dB
* Frequency Range: 31.5Hz to 8.5KHz
* Linearity Range: 50dB/100dB
* Bar Graph
50dB scale at 1dB step for monitoring current sound pressure level
Sample Rate: 20times/second
* Overload Indication: OVER/UNDER
* Frequency Weighting: A and C
* Digital Display: 4 digits
* AC Signal Output: 0.707Vrms at FS output impedance approx. 600Ω(ohm)
* DC Signal Output: 10mV/dB, output impedance approx. 100Ω(ohm)
* Time Weight: FAST / SLOW
* Microphone: 1/2" Electrinic Condenser microphone
* Max hold function: Yes
* Operating Condition: 0~40°C, 10~80%RH
* Storage Condition: -10~60°C, 10~70%RH
* Power Supply: 4 x AA 1.5V alkaline battery (included) or DC 6V 100mA (maxumim DC9V) (not included)
* Battery Power Life: About 30 hours (alkaline battery)
* Size: 256 x 70 x 35mm
* Weight (Meter with Sponge Ball/Windscreen Filter): 230g (excluding batteries)

Feature


* Measuring Level: 30-130dB (A) , 35-130dB (C)
* With Software CD & USB Cable, for recording date into your PC( only for model BE844)
* Level Ranges: 30-80dB ;50-100dB ;60-110dB ;80-130dB ;30-130dB
* Accuracy: ±1.5dB (under reference conditions)
* Resolution: 0.1dB
* Frequency Range: 31.5Hz to 8.5KHz
* Linearity Range: 50dB/100dB
* Bar Graph
50dB scale at 1dB step for monitoring current sound pressure level
Sample Rate: 20times/second
* Overload Indication: OVER/UNDER
* Frequency Weighting: A and C
* Digital Display: 4 digits
* AC Signal Output: 0.707Vrms at FS output impedance approx. 600Ω(ohm)
* DC Signal Output: 10mV/dB, output impedance approx. 100Ω(ohm)
* Time Weight: FAST / SLOW
* Microphone: 1/2" Electrinic Condenser microphone
* Max hold function: Yes
* Operating Condition: 0~40°C, 10~80%RH
* Storage Condition: -10~60°C, 10~70%RH
* Power Supply: 4 x AA 1.5V alkaline battery (included) or DC 6V 100mA (maxumim DC9V) (not included)
* Battery Power Life: About 30 hours (alkaline battery)
* Size: 256 x 70 x 35mm
* Weight (Meter with Sponge Ball/Windscreen Filter): 230g (excluding batteries)

Specification
UNIBOY-E

UNIBOY-E



















Description

Palm-sized with a built-in probe type, a key -lock function
Probe built in a body
Easy to operate zero・standard adjustment with one touch key
Grip-friendly shape

Feature

Anodic oxide coating/ general coating/ lining

Spesification



  • Measuring range  :   0~900μm
  • Resolution  :   1μm
  • Accuracy  :   ±1μm to a flat level or ±3% the indicated value
  • Display method  :   LCD digital, with a display-hold
  • Probe  :   one point contact constant pressure type with V-groove (built-in)
  • Min. measurable area  :   φ18
  • Power  :   Dry batteries (R03 1.5V)×2, auto-power off
  • Temperature  :   0~40℃(non-condensing)
  • Weight and Dimensions  :   56(W)×109(H)×34(D) mm, 140g 
  • Additional function  :   0.1μm unit by switching (below 100μm)
  • Accessories  :   thickness standards, zero plates for test
Sound Level Meter SL4200

Sound Level Meter SL4200




















Description

This high-precision high quality high accuracy Sound Level Meter (30 to 130 Decibels) has been designed to meet the measurement requirement of Safety Engineers, Health, Industrial Safety offices and Sound Quality control in various environment.

Feature
  • * Microphone:1/2 inch electret condenser
  • * Display:3 1/2 digits LCD display
  • * Resolution:0.5dB
  • * Sampling time:0.5 second
  • * Time Weighting:FAST 125ms
  • SLOW 1 second
  • * Measuring ranges:
  • Range 1:(30)32dB to 70 dB
  • Range 2:60dB to 100 dB
  • Range 3:90dB to 130 dB
  • * Accuracy:±2dB(94dB@1kHz)
  • * Dynamic range:40dB
  • * Overflow indictor
  • * MAX hold: "MAX"
  • * Power supply: one 9V battery (model 6F22)
  • * Operating environment:
  •   Temperature: 0-40℃(32-104°F)
  •   Relative humidity: ≤75%RH


Coating Thickness Gauge TT210

Coating Thickness Gauge TT210

















Description

TT210 Coating Thickness Gauge can nondestructively measure the thickness of non-magnetic coatings (such as zinc, aluminum chrome, copper, rubber, paint and so on) on ferrous metals (such as steel, iron, alloyed metals, hard magnetic steel and so on). It can also measure the thickness of non-conducting coatings (such as rubber, paint, plastic, anode oxide film and so on) on the non-ferrous materials (such as copper, aluminum, zinc, tin and so on). It can fast, exactly and nondestructively measure the thickness of coating and plating. It is supplied with testing certificate.

Feature

• Two measuring methods: magnetic induction (F) and eddy current (N) Click here for details
• Magnetic induction (F) method is used to measure the thickness of non-magnetic coating on ferrous metal
• Eddy current (N) method is used to measure the thickness of non-conducting coating on non-ferrous materials
• Automatic recognition of substrate
• Automatic selection of measuring methods
• 5 statistical ways: Mean values / Max. values / Min. values / testing numbers.(No.) / standard deviations (S.DeV)
• Upper-lower limit setting and sound alarm
• Data output to printer or PC by RS232 cable
• 500 readings can be stored
• 2 measuring modes: continuous / single
• 2 stop ways: Manual/automatic
• With software for data analysis

Spesification


Probe typesFN
Measuring methods:magnetic inductioneddy current
Measuring range:0 to 1250 μm0 to 1250 μm
0 to 40μm (for chromeplate on copper)
Minimum resolution:0.1μm
Tolerance :One point calibration±(3%H+1)± (3%H+1.5)
H means the thickness of tested piece
Two points calibration±[(1~3)%H+1]±[(1~3)%H+1.5]
H means the thickness of tested piece
Measuring conditionMin. curvature radius (mm)Convexity 1.5Convexity 3
Min. testing area diameter (mm)Φ7Φ5
Critical thickness of substrate0.50.3
Power supplyBattery AAA 1.5V  (2pcs)
Working Temperature0-40°C
Dimensions110mm×50mm×23mm
Weight100g
SL4201

SL4201




















Description
tingkat suara meter, meter suara, pengukur Suara, pengukur Gelombang Suara, mengukur getaran Suara. Alat uj Suara

Feature


  • Dirancang sesuai dengan Komite Electrician Standar Internasional IEC 651
  • TYPE 2, ANSI S1.4 TYPE 2
  • Liar Rentang Pengukuran: 30-130dB
  • Kaca / spons bola untuk menyaring-out sinyal yang tidak diinginkan
  • Dengan grafik Bar & Overload Indikasi (Over / Under)
  • Dengan 2 setara tingkat tekanan suara berbobot A dan C
  • Sebuah pembobotan frekuensi untuk pengukuran tingkat suara umum
  • C Frekuensi pembobotan untuk memeriksa konten frekuensi rendah suara
  • AC & DC sinyal output analogi tersedia menghubungkan ke frekuensi analisa
  • tingkat perekam, FFT analyzer dan merekam grafis
  • Layar LCD besar dengan angka membaca
  • Cepat dan Lambat modus karakteristik dinamik
  • Nilai maksimum memegang fungsinya untuk mengunci pembacaan
  • maksimum
  • Dynamic tingkat rentang suara & indikasi baterai
  • Penyimpanan data
  • Dengan antarmuka

Spesification
  • Rentang frekuensi: 31.5Hz ke 8KHz
  • Rentang pengukuran: (28) 30-130dB
  • Frekuensi Bobot: A / C
  • Mikrofon: 1/2 inci polarisasi kapasitansi mikrofon
  • Digital Display: 4 digit LCD
  • Resolusi: 0.1dB
  • Tampilan Update: 2 kali / detik
  • Waktu Bobot: 125ms CEPAT

SLOW 1 detik
Mengukur rentang:
  • Kisaran 1: (28) 30dB sampai 70 dB
  • Rentang 2:60 dB sampai 100 dB
  • Rentang 3:90 dB sampai 130 dB
Digital Thermometer 6802 II

Digital Thermometer 6802 II


















Description
Termometer digital dapat menampung berbagai K-jenis kiat termokopel yang cocok untuk berbagai jenis industri dan komersial aplikasi pengukuran temperatur seperti kiln, Oven, Furnace, Panas Memperlakukan, Keramik, Keramik, Logam cair, Crucible dan banyak lainnya.

Kisaran suhu: -50 ° C sampai 1300 ° C (-58 ° F - 2372 ° F)
Resolusi: 0.1 ° C atau 0,1 ° F
Akurasi: ± 0.4 ° ??C ± 1%

Fungsi khusus:

a. Auto Power Shut Off
b. Data Tahan Fungsi
c. Switchable ° C atau ° F atau K
d. Rendah Indikasi Baterai
e. MIN / MAX / AVG
f. T1, T2, Dua K-Type
g. Suhu Pengukuran Diferensial (T1-T2)
h. Dua Ketik "K" Thermocouple input

Ambient Rentang Operasi: 0-40 ° C (32-104 ° F)
Kelembaban relatif: 0-70% RH
Power supply: 9V x1 Baterai
Berat: approx. 300g
Dimensi: 149 x 71 x 41mm


Feature
  • 3 mode suhu: ° C, ° F dan K
  • Satu tombol untuk beralih antara ° F / ° C / K mode juga untuk beralih antara MAX / MIN / AVG
  • 2 saluran suhu: T1 / T2
  • Diferensial pengukuran temperatur
  • K-Type Thermocouple menawarkan akurasi yang baik dan respon yang cepat
  • Tahan Fungsi mode & Tahan indikator
  • Overload peringatan tampilan jika input melebihi rentang pengukuran yang dipilih
  • Dilengkapi dengan sarung karet yang melindungi meter dari dampak desain portabel dan kompak
  • Memungkinkan mudah dan aman penggantian baterai
  • 2 lembar Ketik "K" sensor termokopel


Spesification


Kisaran suhu: -50 ° C sampai 1300 ° C (-58 ° F - 2372 ° F)
Resolusi: 0.1 ° C atau 0,1 ° F
Akurasi: ± 0.4 ° ??C ± 1%

Fungsi khusus:

a. Auto Power Shut Off
b. Data Tahan Fungsi
c. Switchable ° C atau ° F atau K
d. Rendah Indikasi Baterai
e. MIN / MAX / AVG
f. T1, T2, Dua K-Type
g. Suhu Pengukuran Diferensial (T1-T2)
h. Dua Ketik "K" Thermocouple input

Ambient Rentang Operasi: 0-40 ° C (32-104 ° F)
Kelembaban relatif: 0-70% RH
Power supply: 9V x1 Baterai
Berat: approx. 300g
Dimensi: 149 x 71 x 41mm

SL4201

SL4201



















Description

Untuk memesan, silahkan tekan tombol ORDER. Anda bisa memesan barang secara Online.

Anda juga bisa memesan via telephone. Silakan hubungi sales consultant, Hotline kami di, (021) 8611444 sales Consultant kami akan menjelaskan detail produk dan harga terbaru. atau email ke alamat sales@alatuji.com

tingkat suara meter, meter suara, pengukur Suara, pengukur Gelombang Suara, mengukur getaran Suara. Alat uj Suara

Feature

  •  Dirancang sesuai dengan Komite Electrician Standar Internasional IEC 651
  •  TYPE 2, ANSI S1.4 TYPE 2
  •  Liar Rentang Pengukuran: 30-130dB
  •  Kaca / spons bola untuk menyaring-out sinyal yang tidak diinginkan
  •   Dengan g
TT220 ( Discontinue Model )

TT220 ( Discontinue Model )


















Description

TT220 is discontinue. The replacement model is TT290
Alat ukur ketebalan lapisan seperti cat, epoxy, kertas, plastik dan lain-lain dengan range tidak melebihi 1.25 cm.

Feature
  • TT220: integrated probe F, Measuring method: magnetic induction
  • TT230: integrated probe N, Measuring method: eddy current
  • 2 measurement modes: continuous / single 
  • 5 statistical ways: Mean values / Max. values / Min. values / testing numbers.(No.) / standard deviations (S.DeV)
  • 15 measurement readings stored
  • Low battery indication
  • Automatically switch off 
  • Real time or batch printing
Sound Level Meter C.A 834

Sound Level Meter C.A 834

















Description

The C.A 834 Recording Sound Level Meter is designed to evaluate acoustic environments or noise pollution in compliance with the applicable legislation.

Built in a compact, rugged casing, it has a very large recording capacity: 32,000 values

Spesification


- Compliance with IEC 651 type 2
- 4 measurement ranges: 30 to 130dB
- Accuracy: ±1.5dB
- Resolution: 0.1dB
- 2 integration times: fast and slow
- 2 weighting curves: dB(A) et dB(C)
- Memory: 32,000 values
- Acquisition rate: 1s to 1h
- RS232 output: data extraction, possibility of control from a PC to increase recording capacity
- Tripod mounting
- Supplied with data processing software
- Dimensions 205 x 60.5 x 38mm / weight: 230g




Coating Thickness Gauge TIME2600

Coating Thickness Gauge TIME2600


















Description

TIME2600 Coating Thickness Gauge can nondestructively measure the thickness of non-magnetic coatings (such as zinc, aluminum chrome, copper, rubber, paint and so on) on ferrous metals (such as steel, iron, alloyed metals, hard magnetic steel and so on). It can also measure the thickness of non-conducting coatings (such as rubber, paint, plastic, anode oxide film and so on) on the non-ferrous materials (such as copper, aluminum, zinc, tin and so on). It can fast, exactly and nondestructively measure the thickness of coating and plating.


Feature

• Two measuring methods: magnetic induction (F) and eddy current (N)
• 6 types of probes are available for various applications
• 2 measurement modes: continuous / single
• 5 statistical ways: Mean values / Max. values / Min. values / testing numbers.(No.) / standard deviations (S.DeV)
• 640 measured values can be stored
• Integrated with printer for convinient use
• Low battery indication
• 2 switch off modes: manual and auto


Spesification


Measuring rangeRefer to the table below
Probes available
Tolerance
Minimum resolution:
Measuring condition
Operation languageEnglish
StandardsDIN, ISO, ASTM,BS
CalibrationZero and foil calibration
StatisticsNumber of measurements, mean, standard deviation,maximum and minimum of 3000 readings
Data memory640 readings
LimitsAdjustable with alarm
InterfaceRS-232
Working temperature0-40?
power supplyNiMHrechargeable batteries 1.25V
Dimensions230mm×86mm×47mm
WeightApprox. 530g

Weather Station

Weather station adalah pengamatan cuaca dengan instrumen dan peralatan pengujian cuaca untuk mengamati kondisi atmosfer Bumi untuk memberikan informasi prakiraan cuaca suatu wilayah atau tempat dan juga untuk mempelajari cuaca dan iklim suatu wilayah/daerah

Temperature Data Loggers

Temperature Data Loggers atau Microlite digunakan untuk mengukur dan melogger kondisi lingkungan seperti temperatur (suhu). Microlite adalah berupa instrument temperature logger yang berupa USB berukuran mini untuk memantau dan merekam temperatur dalam kondisi lingkungan apapun. Mudah penggunaannya cukup plug and play, data temperatur suhu akan ditampilkan pada layar berupa angka.

Ultrasonic Flaw Detector

digunakan untuk mendeteksi retakan tersembunyi, void, porositas, dan diskontinuitas internal lainnya dalam logam, komposit, plastik, dan keramik. Gelombang suara frekuensi tinggi mencerminkan dari kelemahan dalam hal prediksi, mengetahui pola gema yang khas yang dapat ditampilkan dan direkam oleh instrumen portabel dari perangankat ULTRASONIK FLAW DETEKTOR

 
Copyright © 2016. NDT ALAT UJI | INDONESIA